• 3/2 Nah Pumping Slurry From Conditioning Tank to Flotation Cell
  • 3/2 Nah Pumping Slurry From Conditioning Tank to Flotation Cell
  • 3/2 Nah Pumping Slurry From Conditioning Tank to Flotation Cell
  • 3/2 Nah Pumping Slurry From Conditioning Tank to Flotation Cell
  • 3/2 Nah Pumping Slurry From Conditioning Tank to Flotation Cell
  • 3/2 Nah Pumping Slurry From Conditioning Tank to Flotation Cell

3/2 Nah Pumping Slurry From Conditioning Tank to Flotation Cell

After-sales Service: Yes
Warranty: 1 Year
Max.Head: 50-80m
Max.Capacity: >400 L/min
Driving Type: Motor
Impeller Number: Single-Stage Pump
Customization:
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
3/2 NAH
Working Pressure
High Pressure Pump
Influent Type of Impeller
Single Suction Pump
Position of Pump Shaft
Horizontal Pump
Pump Casing Combined
Horizontal Split Pumps
Mounting Height
Suction Centrifugal
Impeller
Open
Usage
Pump, Pumps, Condensate Pump, Slurry Pump, Circulating Pump
Product Name
3/2 Nah Pumping Slurry From Conditioning Tank to F
Wet End Parts
High Chrome Alloy
Size
2′′x3′′
Drive Type
CV/Dcz/Zvz/Crz
Seal Type
Packing Gland/Expeller/Mechanical Seal
Transport Package
Wooden Case
Specification
3/2C-AH
Trademark
Naipu
Origin
China
HS Code
8413701090
Production Capacity
500sets/Month

Product Description

3/2 NAH Pumping slurry from conditioning tank to flotation cell 

Naipu® NAH series centrifugal slurry pumps and spare parts can fully interchange.These pumps are of heavy-duty construction,designed for continuous pumping of highly abrasive and corrosive slurries.They feature a wide choice of replaceable abrasion resistant metal or moulded elastomer casting liners and Impellers,which are all interchangeable within a common casting assembly.

1.Double Liner Centrifugal Pump
2.Rubber or high chrome alloy impeller
3.Large flow in medium head
4.Drive type:ZV CV DC CR CL
5.Types of 4 seal to prevent leakage:Packing Seal # Expeller Seal # Mechanical Seal # Dyna Seal



Typical Applications----
Minerals Flotation Processing
Electric Factory Coal Preparation
Coal Washing
Chemical Medium Processing
Effluent Handling
Salt and Sugar IndustrySand And Gravel Handling


Construction Drawing

3/2 Nah Pumping Slurry From Conditioning Tank to Flotation Cell3/2 Nah Pumping Slurry From Conditioning Tank to Flotation Cell

 
LINERS IMPELLERS CASING BASE EXPELLER EXPELLER RING SHAFT SLEEVE SEALS
Standard Chrome Alloy
Natural Rubber
Chrome Alloy
Natural Rubber
SG Iron SG Iron Chrome Alloy
or
SG Iron
Chrome Alloy
or
SG Iron
SG Iron Rubber
and
Nitrile
Options Ferralium
Hastelloy C
316 SS
W151
Polyurethane
Neoprene
Butyl
Viton
Nitrile
EPDM
Hypalon
Ferralium
Hastelloy C
316 SS
W151
Polyurethane
Neoprene
Butyl
Nitrile
Hypalon
SG Iron
Various grades
MS
Fabricated
Cast Iron
NI Resist
Ferralium
Hastelloy C
Polyurethane
316 SS
W151
NI Resist
Ferralium
Hastelloy C
316 SS
Rubber
W151
Polyurethane
Neoprene
Butyl
Nitrile
EN56C
Ferralium
Hastelloy C
Titanium
316 SS
304 SS
Ceramic
Stellite
Chrome Oxide
Nordel
Neoprene
Viton



Pump Performance Parameters

Naipu® NAH METAL LINER PUMP WORK PARAMETER
Type Allowable Mating Max.Power(Kw) Clear Water Performance Impeller
Capacity/Q m³/hr Head/m Speed/rpm Max Efficiency/% NPSH/m Nos of Vane Impeller Diameter/mm
1.5/1NAH 15 12.6--28.8 6--68 1200--3800 40 2--4 5 152
2/1.5NAH 15 32.4--72 6--58 1200--3200 45 3.5--8 5 184
3/2NAH 30 39.6--86.4 12--64 1300--2700 55 4--6 5 214
4/3NAH 30 86.4--198 9--52 1000--2200 71 4--6 5 245
6/4NAH 60 162--360 12--56 800--1550 65 5--8 5 365
8/6NAH 300 360--828 10--61 500--1140 72 2--9 5 510
10/8NAH 560 612--1368 11--61 400--850 71 4--10 5 686
12/10NAH 560 936--1980 7--68 300--800 82 6 5 762
14/12NAH 560 1260--2772 13--63 300--600 77 3--10 5 965
16/14NAH 1200 1368--3060 11--63 250--550 79 4--10 5 1067
20/18NAH 1200 2520--5400 13--57 200--400 85 5--10 5 1370



3/2 C- NAH  Main Parts List
 
3/2C-NAH Shaft Sleeve C075
Base  C003M
Lantern Ring C063
Lantern Restrictor C118
Packing Seal C067
Frame Plate  C2032
Cover Plate C2013
Impeller  C2147
Volute C2110NA
Frame Plate Liner Insert  C2041
Shaft Spacer C117
Stuffing Box C078
Expeller  C028
Expeller Ring  C029
Suction Gasket  C2060
Discharge Gasket C2132XLP
Volute Liner Seal C2125
Seal Ring C122
Labyrinth Ring C108
Oil Cup Base D138
Bearing Housing C004M
End Cover C024
Grease Retainer C046
Labyrinth Sleeve C062
Shaft  C073M
Bearing Assembly C005M




Product Overview:

For the AH pump types,we can provide as below,

1.5/1B-AH(R)  2/1.5B-AH(R) 3/2C-AH(R) 4/3C-AH(R) 6/4D-AH(R) 6/4E-AH(R) 8/6E-AH(R)
8/6R-AH(R)  10/8F-AH(R)  10/8ST-AH(R)  12/10ST-AH(R)  12/10FF-AH(R)  14/12G-AH(R)
14/12ST-AH(R)  16/14TU-AH(R)  20/18TU-AH(R)



3/2 Nah Pumping Slurry From Conditioning Tank to Flotation Cell



Our Workshop Show:

NAIPU PUMP is a whole processing company, Start from Modeling Workshop,Casting Workshop,Heat treatment Workshop,Machining Workshop ,Assembly Workshop and Pump Testing Workshop are all by us. So we are modernization and integrated company to satisfy the requirement of the changing needs of market.

We set various check points along the whole production line,which throughout Raw Material,Charging Material,Surface and Heat Treatment checking,Material Analysis,Spare Testing and Pump Testing etc.
3/2 Nah Pumping Slurry From Conditioning Tank to Flotation Cell





Possible Faults and Settlements 
 
        Faults      Reason        Settlement
1.Pump fails to discharge any water,The hand of pressure gauge beat violently  1.Suction pipe don't have enough water.
2.Suction pipe blocked or the valve is locked.
1. Inject enough water
2.unlock the inlet valve,clear the blocks
3.Exclude the air leakage 
2.The pump can't discharge water,the hand of vacuum meter beat heavily.  1.The inlet valve is unlocked or silted up.
2.The resistance of suction pipe is too big or silted up.
3.The height of suction is too high. 
1.Unlock the valve or desilting 
2.improve the design of  suction pipe or desilt 
3.Lower the height of the installation.
3.The pump can't discharge water,pressure gauge shows heavy pressure. 1.The resistance of the discharge pipe is too big.
2.The impeller blocked
3.The speed is slow.
1.Check and adjust the outlet pipe.
2.Clear the impeller
3. Improve the speed.
4.The pump doesn't rotate  The volute is silted up by the blocks.  Clear the blocks
5.The capacity is not enough  1.The blocks of the impeller or the inlet or outlet pipe.
2.The abrasion of the impeller is heavily.
3.The speed is low to normal 
4.Pump is installed unreasonably or the leakage of the inlet pipe.
5.The transporting height is too high,the loss of the resistance of the inside pipe are too big.
6.The inlet valve not open enough or blocked
7.The packing seal leaks
1.Clear the impeller or pipe.
2.Change the impeller


3.Adjust the speed
4.Install again or stop leaking.

 
  1. Decrease the height of the transport or reduce the resistance.
  2. Unlock the inlet valve
 
  1. Compress the packing tightly
6.The motor of the pump is overloaded  1.The head of the pump exceeds the head of the working condition.
2.Not consider the slurry density when selecting the pump.
3.The packing press tightly
1.Turn down the outlet valve,cut the impeller or lower the speed.
2.Select the motor again.
3.Adjust the the screw of the  packing gland 
7.Abnormal sound in the pump, and no water out 1.The resistance of the inlet pipe is too big.
2.The height of the suction is too high.
3.Cavitation occurred 
  1. there is air in the inlet
  2. The temperature of the liquid is too high
  1. Clear the suction pipe and sluice valve.
  2. Lower the height of the suction 
  3. Adjust the water valve and let the pump operate in the defined limits.
  4. Block the leakage.
  5. Lowering the liquid temperature.
8.pump vibrates 1.pump cavitate 
2.The block of the impeller single vane 
3.The no concentricity  between the pump shaft and motor shaft
4.Fasteners or foundation loose
1.Adjust the water valve ,lower the height of the installation,reduce the resistance of the inlet.
2.Clear the impeller
3.Alignment again
4.Fasten the screw,and reinforce the foundation.
9.Bearing is overheat  1.lock the cooling water
2.lubrication is not good.
3.the lubrication oil is not clear
4.the wrong direction of the thrust bearing.
5.there is something wrong with the bearing.
  1. Open the cooling water
  2. Adjust the oil quantity 
  3. Clear the shaft,change oil
  4. According to the inlet pressure,adjust the direction of the thrust bearing.
  5. Change the bearing 
10.Packing short life  The material of packing is not good  Change the packing 
11.pump leak oil 1.High oil level
2.The rubber parts invalid  
3.Assembly problem
1.Lower the oil level
2.Change rubber spares
3.Adjust the assembly
 
12 Pump head leaking  1.The rubber parts not press well Assembly again or press tightly 


Applications

Heavy Mining | Mineral Processing | Sand and Gravel |Coal Prep | Cyclone Feeds | Aggregate Processing | Fine Primary Mill Grinding | Chemical Slurry Service | Tailings | Secondary Grinding | Industrial Processing | Pulp And Paper | Food Processing | Cracking Operations | Ash Handling | Pipeline Transport | High Velocity Hydraulic Transport |Food Processing | Explosive Sludge In Metal Smelting | River And Pond Dredging | Heavy Refuse Removal | Larger Particle Or Low NPSHA Applications | Continuous (Snore) Sump Pump Operation | Abrasive Slurries | High Density Slurries | Large Particle Slurries | Sump Drainage | Wash down | Floor Drainage | Mixing | Iron Ore | Cooper | Diamond | Alumina | Coal | Gold | Kaolin | Phosphorite | Steel | Palm | Suger | Chemical | Power | FGD | Frac Sand Blending | Construction | City Sewage | etc. 
3/2 Nah Pumping Slurry From Conditioning Tank to Flotation Cell


Contact Us 

Contact Person: Karen Tan  


 




 


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory
Management System Certification
ISO 9001, ISO 9000, ISO 14001
OEM/ODM Availability
Yes